Skip to content

Review the optimal charge follow-up

≈ 6 min readIntermediateChecked against Zap on November 11, 2026

Seguimiento de la carga óptima (Optimal charge follow-up) checks how the Optimal charge advisor would have done on a period’s heats. By product, it compares two things:

  • The chemistry: the first reading each charge predicted against the one ARL measured.
  • The cost: what each usable kg cost against the cheapest charge that could have been put together with what was in stock.

The screen only looks things up: it changes nothing. It shows costs, so it is for internal use.

To get there, search for Seguimiento de la carga óptima with Ctrl+K (⌘K on a Mac), or press the Seguimiento: qué tan bien prevé… (Follow-up: how well it predicts…) link on the Carga óptima screen. From this screen, Calcular una carga (Calculate a charge) takes you back to Optimal charge.

  1. On opening, Zap already calculates the whole previous month. While it calculates it says «Calculando. Puede tardar: se rehace la química estimada y se consulta ARL.» (Calculating. It may take a while: the estimated chemistry is rebuilt and ARL is queried.)

  2. For another period, change Desde (From) and Hasta (incluido) (To, inclusive). No date can be later than today, and the period can be up to 92 days.

  3. Press Calcular (Calculate).

If you came from Optimal charge with a product chosen, you only see that product. Todos los productos (All products) removes the filter.

At the top, a summary gives the Periodo (Period) and how many heats it had. It also says from which date the estimated chemistry comes: from the heats of the 180 days before the period. That way, the prediction never saw the heats it is compared with.

Two notices can show in the same summary:

  • «Sin primera lectura utilizable (solo se compara su costo): …» (No usable first reading, only its cost is compared: …): how many heats have no reading to compare the chemistry with, and why.
  • «… con coladas en el periodo no tienen especificación activa con rangos de liberación: no se siguen.» (… with heats in the period have no active specification with release ranges: they are not followed.): those products do not appear below.

Then comes one card per product. The products with the largest savings opportunity come first, and those that cost less than the advisor come last.

The first line of each card sums up the cost, for example:

  • «Con la carga del asesor, … menos por kg útil en … coladas: … en el periodo.» (With the advisor’s charge, … less per usable kg over … heats: … in the period.): what would have been saved.
  • «Lo cargado costó … menos por kg útil que la carga del asesor en … coladas: el asesor mantiene cada elemento en su rango de liberación.» (What was charged cost … less per usable kg than the advisor’s charge over … heats: the advisor keeps each element within its release range.): the real charge came out cheaper.
  • «Ninguna colada se pudo comparar con la carga del asesor.» (No heat could be compared with the advisor’s charge.)

Below, in small print, the cost per usable kg of Lo cargado (What was charged) and of el asesor (the advisor). Both use the same costs and losses: the difference is the mix, not the prices.

Predicted first reading against the real one

Section titled “Predicted first reading against the real one”

One row per element:

ColumnWhat it says
Coladas (Heats)How many heats were compared for that element.
Error medio (Mean error)The average distance between the predicted reading and the real one.
Sesgo (Bias)Which way it errs: «(sale alta)» (comes out high) or «(sale baja)» (comes out low).
Ancho del rango (Range width)The width of the element’s release range.
Dentro de medio rango (Within half a range)In what percentage of the heats the prediction fell less than half a range from the real one.
Para planear (For planning)«Sirve» (Usable) from 80 %, «Con reservas» (With reservations) from 50 % and «No sirve» (Not usable) below 50 % (in red).

If it says «Ninguna colada tuvo una primera lectura utilizable con la química de casi toda su carga.» (No heat had a usable first reading with the chemistry of almost all its charge.), there was nothing to compare that product’s chemistry with. To compare, at most 10 % of the charge’s kg can lack chemistry.

Open Detalle por colada (Detail by heat) to see each heat: Colada (with a link to the heat), Inicio (Start), Kg cargados (Kg charged), Prevista → real (Predicted → real) by element, Costo por kg útil (Cost per usable kg), El asesor (The advisor), Oportunidad (Opportunity) and a Nota (Note).

The Nota says what the row is missing, for example:

  • «Sin primera lectura utilizable» (No usable first reading) or «… % de los kg sin química: sin previsión» (… % of the kg without chemistry: no prediction): the chemistry is not compared.
  • «Sus materias no tienen costo.» (Its materials have no cost.) or «… % de sus kg sin costo: no se compara.» (… % of its kg without cost: not compared.): the cost is not compared.
  • «Solo caldo y reproceso: no hubo kg que elegir.» (Only molten metal and rework: there were no kg to choose.)
  • «Ninguna materia en existencias tenía química y costo.» (No material in stock had chemistry and cost.)

A negative Oportunidad means what was charged cost less than the advisor.

MessageWhat to do
«No hubo coladas en el periodo.» (There were no heats in the period.)Choose another period.
«Ningún producto del periodo tiene especificación con rangos de liberación.» (No product in the period has a specification with release ranges.)Quality sets up the specification in Calidad → Especificaciones (Specifications) (Alloys and model charges).
«El periodo es de … días; el máximo es 92.» (The period is … days; the maximum is 92.)Shorten the period.
««Hasta» (…) no puede ser anterior a «Desde» (…).» («To» cannot be earlier than «From».)Set Hasta (incluido) on the same date as Desde or later.
«ARL no respondió y la química estimada lo necesita; intenta de nuevo en unos minutos.» (ARL did not respond and the estimated chemistry needs it; try again in a few minutes.)Wait a few minutes and press Calcular.
«No se pudo calcular el seguimiento de la carga.» (The charge follow-up could not be calculated.)Press Calcular again. If it persists, tell IT.
Next stepCalculate a furnace's optimal charge