Skip to content

Review the statistical process control (SPC) of the chemistry

≈ 4 min readIntermediateChecked against Zap on November 11, 2026

Control Estadístico de Proceso (SPC) (Statistical process control) measures, by alloy and element, how capable the process is of staying within the specification (Cp/Cpk) and whether it is stable. It uses the chemical analyses of each alloy’s heats, oldest to newest.

It is an advisor: it does not block the release of any heat.

To get there, open the Calidad (Quality) menu → Trazabilidad (Traceability) → Control estadístico (SPC), or search for it with Ctrl+K (⌘K on a Mac).

  1. Open the screen. Zap shows the last calculated capability; it does not recalculate it on opening. While it loads it says «Cargando capacidad de proceso…» (Loading process capability…).

  2. Check the four counters at the top: Crítico (Critical), Advertencia (Warning), Capaz (Capable) and Sin datos (No data).

  3. Check the Capacidad por aleación×elemento (menor Cpk primero) (Capability by alloy×element, lowest Cpk first) table. Unsorted, the worst come first: Critical first, then Warning, then Capable and No data last; within each status, the lowest Cpk first.

  4. To sort another way, press the Aleación / Elemento (Alloy / Element), Cpk / Cp, n or Reglas (Rules) header. The table shows 10 rows per page.

At the bottom, Última actualización (Last update) says when the capability was calculated, not when you opened the page.

ColumnWhat it says
Estado (Status)The status and the Cpk. An orange icon marks «Fuera de control estadístico» (Out of statistical control).
Aleación / ElementoThe specification and the element’s symbol.
Cpk / CpThe capability. It says «sin espec» (no spec) if the specification has no limits for that element.
Media ± σ (Mean ± σ)The process average and deviation.
Límites (UCL/LCL) (Limits)The upper and lower control limits.
Especificación (Specification)The specification’s minimum and maximum and, if it has one, the target (obj.).
nHow many measurements there are. «insuf.» means fewer than 20: not enough for stable limits.
ReglasHow many Nelson rules fired. Press the number to open the detail.

Some columns only show on wide screens.

StatusWhen
CapazCpk of 1.33 or more and no rule fired.
AdvertenciaCpk between 1.00 and 1.33, or some rule fired.
CríticoCpk below 1.00, or a point beyond 3σ (rule 1).
Sin datosFewer than 20 measurements.

If the element has no limits in the specification, the status comes from stability alone: Critical with a point beyond 3σ, Warning with any other rule, Capable with no rules.

  1. In the Reglas column, press the row’s number.

  2. The detail of that alloy and element opens below the table:

    • Gráfico de individuos (I) (Individuals chart, I): each measurement in order, with the Media (Mean) and the UCL/LCL limits.
    • Reglas de Nelson disparadas (Nelson rules fired): each rule with how many times it fired and desde el punto #… (from point #…). If there are none, it says «En control estadístico — sin reglas disparadas.» (In statistical control: no rules fired.) With fewer than 20 measurements (Sin datos) it says «Con … puntos aún no se evalúan las reglas de Nelson: no se sabe si está en control estadístico.» (With … points the Nelson rules are not evaluated yet: it is not known whether it is in statistical control.)
  3. To close it, press the detail’s X or the same number again. The detail also closes when you sort or change page.

Press Recalcular (Recalculate) to calculate the capability again with the analyses recorded so far. While it works it says Recalculando… (Recalculating…). Read permission on Quality is enough: the calculation does not change any analysis.

MessageWhat to do
«No hay capacidad calculada aún — presiona «Recalcular» para calcularla (requiere especificaciones de aleación activas con mediciones).» (No capability calculated yet: press Recalculate to calculate it; it needs active alloy specifications with measurements.)Press Recalcular. If it stays empty, no active specification has recorded analyses.
«No se pudo cargar la capacidad de proceso. Intenta de nuevo; si sigue igual, avisa a Sistemas.» (The process capability could not be loaded. Try again; if it stays the same, tell IT.)Reload the page. If it persists, tell IT.
«No se pudo calcular la capacidad de proceso. Intenta de nuevo; si sigue igual, avisa a Sistemas.» (The process capability could not be calculated…)Press Recalcular again. If it persists, tell IT.
Next stepVW quality control (porosity and inclusions)